Monday, July 24, 2017

Product Review - Schneider Xantrex C35 Charge Controller

To protect my 2 x 6v Trojan Batteries, I bought and installed a Schneider Xantrex C35 Charge Controller.

The Controller is fairly easy to setup and it comes with a comprehensive manual. It's very difficult to get stuck with the installation or wrongly configure the controller.

I installed a dump load to divert excessive power. I still have to find or build an aluminium box for the diversion load heater, in fact right now it's just hanging underneath the controller.  The dump load can easily handle 12 amp at 12v.



I have installed the controller a month ago and I can confirm that the batteries have never been overcharged. In this small installation I do have more power then needed and therefore without the controller I'll be boiling the batteries on a daily basis.

The photo below is displaying the 12v Control box and next to it the charge controller.


The dump load has been enclosed in a box...





iMiev AC/Heater consumption

The iMiev is designed to deliver 160KM on a single charge. According to the official iMiev specifications this range can greatly vary depending on a number of factors. 
As detailed below (taken from the iMiev specification small print) , the electric range can and will vary depending on the driving style, traffic conditions. ambient temperature and use of AC.

*2: NEDC stands for New European Driving Cycle. The values of electric energy consumption and electric range are based on UN R101. These values vary depending on driving style, road and traffic conditions, ambient temperature, use of air conditioners and so forth.


I'm gathering statistics on my iMiev on a monthly basis and can confirm that yes, using the A/C or Heater will greatly effect the electric range. 


The photo above was taken on starting the car and with the A/C on. The car was standstill. As can be clearly seen, the Power meter was not on Zero but the needle moved to 'Eco' which means that power was being taken from the traction battery. The consumption is not that high but normally without any A/C switched on, and the needle in that position, I'll be driving the car at 40KM/Hr on a flat surface!
Therefore it is clearly obvious that cooling/heating does consume power from the battery, thus reducing the electric range.
I'm not fanatic about the range I manage to achieve, I'm more interested in driving in comfort.

Wednesday, July 19, 2017

Fire Prevention

If you go through my blog, you'll find out that I have all the house batteries and almost all power electronics installed in my garage (which is physically linked to my house).


The photo above is showing part of my setup. 
  • Burglar Alarm (12v sealed battery inside)
  • 4 x 12 MCB boxes. 240v AC House circuits.
  • 2KW SMA Inverter (Yellow Box)
  • House Power selector switch and meters with surge protectors inside
  • 12v Control Box with a xantrex charge controller c35. All Fused
  • 24v Control Box. All Fused
  • Battery and Inverter Switches
  • Off-Grid Inverter
  • 2 x 500W Grid-tie Inverters
  • 12v Car Battery Charger
  • Battery Box (12 x 2v Forklift Batteries + 2 x 6v Trojan Batteries)
All of the above can catch fire!
Everything is fully fused as it should be and all wires are properly sized to carry the estimated current, however this does not mean that accidents cannot occur... an electronic component malfunctions and the fuse does not blow or blows late after a copper wire catches fire.

To put my mind at rest I installed two fire extinguishers in the garage.
  1. 6kg Dry Powder extinguisher
  2. 5kg CO2 extinguisher
Both can be safely be used on electricity although I'll prefer the CO2. Having said that in large open spaces, the CO2 may not be enough to extinguish the fire and that's why complimenting with a dry powder extinguisher is a good idea.   




Above - 6kg Dry powder


Above - 5Kg CO2


Tuesday, July 18, 2017

Battery Desulfators

Basic technical information.
Basically, lead acid batteries are made up of lead and lead dioxide plates immersed in an electrolyte or sulfuric acid.
During normal use the sulfuric acid reacts with the lead dioxides plates to generate electricity (i.e. power) and in the process a thin layer of solid lead sulfate crystals are deposited on the plates. If inspected, these crystals will cover the battery plates and looks white as shown below.


This hardened lead sulfate is an unwanted product of this chemical reaction and is called sulfation, one of the main reasons why lead acid batteries start loosing capacity and eventually become unable to hold any charge and need to be thrown away. This happens because these large crystals clog the pores of the lead dioxide active material and therefore charging becomes impossible.
During charging, the reverse process occurs and the lead sulfate is converted back to lead dioxide and sulfuric acid, restoring the battery to it's pre-discharge state. Unfortunately, this charging process is not perfect and in fact with every charging/discharging cycle, more sulfate is deposited on the plates and never removed, thus the battery loosing slowly it's original capacity. That's why a battery is also rated on the number of cycles it can sustain. A cycle is considered to be a battery from a charged state, discharged and charged again. Expensive fork lift batteries are rated to sustain > 3000 cycles i.e. if the battery is charged/discharged daily, the battery can survive 8+ years with very little loss of capacity!
A battery desulfator is a device which will clean the batteries internal plates, i.e. it's able to remove the hardened crystals (which were not previously removed by the normal charging process) and restore the battery to a better state, holding more charge and capacity. A good desulfator uses pulse frequency to dissolve these crystals.

There is a lot of literature and videos on the internet about Battery Desulfators however all seem to lack to draw a definite conclusion, do Battery Desulfators really work?

Deep Cycle Batteries are expensive! In fact I preferred to spend extra Euros on the Desulfators in the hope that they will maintain my batteries in better shape and prolong their useful life.

Installation
I opted for these Battery Desulfators from infinitumstore. I like their design, fully enclosed/sealed making them ideal to sit next to batteries. Also these devices use Amplitude Modulated Pulses at the resonance frequency of the crystals to shatter the covalent bonds that hold it together.

I installed 4 desulfators in total, 2 in parallel for the 24v forklift batteries while another 2 desulfators in parallel for the Trojan 12v system.

The image below is showing the installation details.

  • The top 2 desulfators are 12v
  • They are installed just after the 12v battery main switch. I used an old (but unused) 240v AC 45 amp fuse box, containing a 30 and 15 amp fuse inside. I used the 30 amp as the 12v battery main fuse, while the 15 amp fuse holder for the 12v desulfators. I did replace the desulfators 15 amp fuse wire with a 5 amp fuse wire.
  • The bottom 2 desulfators are 24v
  • They are also installed just after the 24v battery main switch. I used an old (but unused) 240v AC 60 amp fuse box, containing two 30 and one 15 amp fuse inside. I paralleled the 30 amp fuses as the 24v battery main fuse, while the 15 amp fuse holder for the 24v desulfators. I also did replace the desulfators 15 amp fuse wire with a 5 amp fuse wire.
  • All components have been fitted to a piece of wood which in turn was fitted against the battery box.



The desulfators have been installed just against the outside of the battery box.







Monday, July 10, 2017

Heatsink Water cooled


Introduction
On upgrading my off-grid 24v system, I added more Photo-Voltaic Panels - 900W in total (150w x 6). I decided to sell this all this power instead of storing it into the batteries. I purchased two small grid-tie inverters - 500W peak  each and connected them to the solar panels and grid. They worked well however I noticed that the inverters were getting pretty warm! The inverters are installed in the garage which is South facing. Therefore the garage is exposed to long periods of direct sunlight, raising the room temperature significantly. I measured the temperature in the afternoon and the mercury hit 35 °C. This was forcing the inverters fan to run continuously besides that the inverters were still getting pretty warm.
I needed to find a way to keep the inverters cooler. One way to do this was to water cool them!
This required a lot of preparation because I needed to have a cold water supply next to the inverters, something which was not readily available.  The water cooling supply has been taken from the roof tank (2 stores higher) and thanks to gravity, I did not need a circulation pump to get the water circulating the inverters. The water after passing through the inverter heat-sinks is then dumped back in the well, thus there is no water wastage. The house water well pump would then switch on occasionally automatically (depending on the roof tank water level) and new cold water is pumped from the well to the tank.
I have this system running for the past month now and must say that I'm really satisfied with it's performance. The main objective has been reached in that the inverters are now running much cooler. A cooler inverter (electronics) will translate to a longer working life. The water is being circulated against the heatsink for most of the day but that's OK as long as the inverters are kept cool.

Built Details
The Inverters have been mounted on a 4mm aluminium sheet. A large heatsink has also been fitted to the back of the aluminium sheet to add in thermal mass. Thermal paste has been used to facilitate heat transfer between the two metals.
Two CPU water cooling blocks (as shown below) have been fitted to the 4mm aluminium sheet to allow cold water to circulate and cool the heatsink/inverters.

One Thermal switch has been fitted to the heat-sink. I have chosen a switch which will operate at 35 °C and reset at 20 °C. Therefore once the heatsink temperature reaches 35 °C , the thermal switch will turn on... switching on the water circulation solenoid.



The picture below is showing the underneath of the inverters heatsink. In the middle, I have attached the heatsink, on the left top corner, I have attached the thermal switch while CPU cooling blocks are the blue blocks attached to either side of the heatsink.



Water flow is controller using a 24v AC solenoid valve. A small transformer has been fitted to power the solenoid since it runs on AC! 
An AC solenoid runs cooler than a DC solenoid and that's why it has been chosen.




The picture below is showing the front of the aluminium sheet with the grid-tie power inverters installed.


The picture below is showing the inverters installed to the wall. On the left there is a consumer box with 2 separate double pole MCBs and a KW power meter to measure the amount of power generated by these inverters.
On the left of the inverters, there are the water connections, water feed and return showing also the solenoid box at the extreme right.



The solenoid box installed. A relay has been used to power the transformer which in turn will power the solenoid valve.















Therefore in summary;
The heatsink will warm up. On reaching 35 °C, the thermal switch will close and this will activate the 12v relay coil. The relay contacts will close and this will activate the 24v AC solenoid valve, opening the water flow.






Trojan 6v T-105 Deep-Cycle Flooded

The 12v system batteries have been replaced with 2 x 6v Trojan Batteries rated 225 Amp-Hours at the 20-HR Rate. Details about these batteries can be found on the Trojan website or here 

The batteries have been installed in the battery box to 
1) Eliminate any accidental contact with the terminals. A short circuit on the terminals can easily promote a fire. If a metal object drops on the terminals, a huge current will pass through it. In a matter of seconds the metal object will get so hot that it would be impossible to remove, it may even weld itself to the terminal blocks. This huge current will cause a huge sudden discharge during which the batteries will get hot and may explode.
2) Deep cycle batteries tend to gas heavily during charging. This gas is highly explosive and a spark can easily ignite the gas causing the batteries to explode. The battery box which I have installed is well vented so this possibility is further reduced.




These batteries will be charged using 2 panels.
thus a maximum of 17 amps charging can be reached during the day. A Schneider Xantrex C35 Charge Controller has been installed in 'Diversion Mode' to protect the batteries from overcharging.

Friday, December 11, 2015

Paris has become Greener.

Last week I was in Paris for a short holiday and on arriving at the airport, the first taxi which I took was a hybrid. At first I thought that it was a coincidence, but then I started noticing that a good percentage of the Paris taxi fleet were actually hybrids ranging from Peugeot, Renault, Citroën to Toyota.

I also noticed that a number of EV charging points have been installed across Paris since my last visit there 2 years ago, with EVs parked and charging. I found out that Paris has introduced an electric car sharing program and through my experience and judging by the EVs which I saw in the streets, I can say that it's being used quite a lot.

In the past 2 years a lot has changed in Paris and now it has become more Green!



Since I happened to be in Paris in December 2015, when the 2015 United Nations Climate Change Conference talks were being held, I was lucky enough to see a large display of Photo-voltaic panels installed in Champs Elysees serving as a demo to the public on the use of the sun to generate electricity.


I also saw a number of new Hyundai ix35 Hydrogen fueled cars (to be used as Taxis) just in front of the Eiffel Tower. Some more details on this initiative can be found here.




Friday, August 28, 2015

13 Amp 2 Gang Double Switched Socket c/w USB

Product Review - 13 Amp 2 Gang Double Switched Socket c/w USB


I bought a couple of these 13 Amp 2 Gang Double Switched Socket c/w USB from TLC Direct some time ago.



I have tried charging mobiles, wireless headphones, tablets and mp3 players with success! These devices do work well. Since the output is limited to 2.1amps, it means that only 1 amp is available per USB port. That's fine for mobiles, headphones and mp3 players however the tablets will take longer to charge due to the smaller charging current.

These Sockets are really cool. You won't be wasting a 13amp outlet for a charger anymore!

Monday, August 3, 2015

The Electric vehicle arrived!

Finally the much awaited Electric vehicle (EV) Arrived. I Obviously went for the Mitsubishi iMiev which I bought from Mitsubishi Motors.
Having thoroughly tested the car for 8 weeks last year as part of  an EU Demo program, funded by the EU, (Demonstration of the Feasibility of Electric Vehicles towards Climate Change Mitigation) Project no. LIFE10/ENV/MT/088), it was the natural electric car for me to buy.

I had blogged about my 8 week experience here.

I have also linked to the Mitsubishi Motors website for a list of the car's features and characteristics.

The EV has been in service for almost a month now and I have started gathering some real-life data here.

Friday, July 17, 2015

EV Charging


To better monitor my EV charging times/electricity consumption, I installed a separate 13amp circuit distribution box in the garage next to the other distribution boxes.
The circuit consists of two (inside) 13amp socket outlets and an external waterproof dual 13amp socket outlet, installed just outside the main door.
All socket outlets are protected by a separate 30ma ERCB (Salvavita) and a 16amp dual MCB. I have also installed a KWH meter to monitor the EV charging requirements and thus be in a better position to calculate the EV running costs.
The EV circuits will be switched OFF when not in use (as indicated by the Orange Neon indicator).

The image below is displaying four of the distribution boxes.
1) Top Left is all dedicated to the house air conditioning circuits.
2) Bottom Left is dedicated to the House 'general' circuits. Main MCB, ERCB, ERCB bypass etc.
3) Top Right is the new distribution box for the EV charging circuits
4) Bottom Right is dedicated to the off-grid Inverter circuit, consisting of a main MCB, ERCB and a KWH meter.




The image below is displaying the EV charging distribution Box. From left to right are the 30ma ERCB, KWH meter and the 16amp MCB. Then there is also a small miniature switch which will be used to illuminate an LED strip outside the house to mark/indicate the cable crossing across the pavement.


The image below is displaying one of the 13amp socket outlets installed inside the garage, clearly indicating that the socket is to be used solely for the EV charging. It is extremely important that the EV sockets are solely used for the EV charging otherwise they will distort the EV charging requirements!

 
 
The image below is displaying the external 13amp socket outlet to be used solely for EV charging


 
 
I dug a culvert right outside my property which will be used to pass the charging cable through. In this way there will be no wires running around on the pavement and therefore less chance of people toppling over it!
I'll place/remove the cable each time I need to charge the EV and therefore the cable is only placed temporarily while the EV is being charged.




 
And here I'm charging the EV at night. Notice how the cable (black) is passing through the culvert.


 
I have also illuminated the culvert (using a water-proof LED strip) to indicate to anyone passing through that the EV is being charged. Although the EV charging socket is illuminated, I decided that I'll better illuminate the area a bit more so people will notice that a socket/cable are coming out from the EV.


Thursday, May 7, 2015

Swimming Pool Solar Heating


I have installed a small (approx. 4000 litres) inflatable pool for my boys in the yard which is used in the Summer months i.e. between June and September.
The pool is exposed to direct sunlight during the morning/early afternoon hours, approx. from 09:00 till 14:00. This would be enough to heat the pool water, however in Summer I cover the yard (and therefore the pool) with shades to reduce the heat inside my house. The problem with shading is that the pool doesn't get heated well anymore and the water can get quite cold, enough for my boys to start feeling cold.
I used to replace some of the pool water on a daily basis by dumping some of the pool water in the grey water tank and replacing it with warm water from the solar water heater, however this year I have a better solution.
I build a small flat plate collector (50cm x 54cm) with a 15 metre 1/2 inch copper pipe inside the collector, all painted matt black. Then I've covered the box with non reflective glass. The theory behind is that I'll be looping the water from the pool through the solar collector, the water gets heated in the process (it will absorb the heat from the collector) and is then dumped back in the pool. The collector is a small one and therefore the pool water can never reach a temperature high enough to scald the boys, however it should be enough to warm the pool water to a more comfortable temperature.
The size of the collector was something which I had little control over simple because it has to be installed in a tight/small space. In theory, at any moment, the sun emits about 3.86 x 1026 watts of energy. Most of that energy goes off into space, but about 1.74 x 1017 watts strikes the earth. (ie: 174,000,000,000,000,000, or 174 quadrillion watts). 
If there are no clouds, then 1 square meter of the earth will receive about one kilowatt of that energy.

The image below is showing the underneath of the solar collector box. I have painted it in gloss white and it will be positioned on a 40mm steel pipe.

 
 
Below is an image of the inside of the solar box, painted matt black.

 

Below is an image of the inside of the solar box, with the 15m copper pipe placed and painted/sprayed matt black as well.
 
 
And below the ready solar collector with the glass installed.
 
 
 
I'll be installing the finished collector and water pool soon. I'll be posting some performance data once it's up and running.
 

Monday, May 4, 2015

Central Inverter vs. Micro-Inverter

Central Inverter vs. Micro-Inverter

I'm writing this post because some time ago a relative of mine requested a quote from a local RE supplier and this company recommended that he should install the panels using micro-inverters. The supplier remarked that 'this is the new way of installing panels.' WHAT? True, the technology may be newer than central inverters but that doesn't mean that the central inverters installation is a thing of the past or that micro-inverters are better than central inverters. Both installation types have their pluses and minuses as I'll detail below.
The price for the whole system using micro-inverters went up quite a bit! The strange thing is that the quote was issued after a site visit and it was confirmed that there are NO SHADING issues. So why use micro inverters when shading is not an issue?
Well, quite difficult to answer on behalf of the supplier; however I would like to make these observations.

1) If all panels are facing the same South direction, then one MPPT controller would be enough. Why spend money to purchase an MPPT controller for each panel? Agreed that although the panels would all be rated the same (Power, Voltage, Current), their performance (including their internal resistance) may vary between them, BUT by how much? I don't think that mismatch in panels is an issue in this case simply because most probably the panels would have come from the same manufacturer/batch. Normally the panels may vary +- by a small percentage and that's all, nothing to bother with regards to their overall performance.

2) If not all panels are facing the same direction, but maybe they are split in half, then there are central inverters with 2 or 3 MPPT controllers built in. These will facilitate the installation of the 2 or 3 sets of panels and therefore individual inverters are not needed.

3) If the panels are scattered on the roof all with different directions, then yes I agree that individual MPPT controllers will be needed to optimize the extracted energy from the panels.

4) If there are shading issues, i.e. during a long time of the day, several panels are covered, then again, individual MPPT controllers might be required.

5) Although Micro-inverters are being offered with a longer warranty, I'm still very suspicious about it. Both type of inverters are built from electronic components and both inverters will be placed on the roof next to the panels. The difference is that the Micro-Inverters are placed under the panels while the central inverter can be better positioned in a much cooler location. Electronic components last longer when working in a cool temperature. Therefore a central inverter, due to its better positioning. should last longer since its electronic components are working at a better 'relaxed' temperature.

6) Suppliers and Manufacturers are quoting a better yield from the system, between 5-20%.
Let's take an example here - a 2KW system consisting of 9 panels at 230W each (my actual installation size).

In this case, a 5% increase means we're talking of an extra 103W (equivalent to half a panel.)
In the case of a 20% increase, we're talking of an extra 414W (equivalent to an extra 2 panels). I'm quite susceptible to the 20% increase, however we'll include it also in the comparisons.

In my opinion, if there are no shading issues as mentioned above, and there is more space on the roof, I'd prefer to add an extra panel or two to make up for the decreased efficiency (which is claimed) than adding the micro-inverters. A panel comes with a 25-year warranty and from my experience, they do stick with their warranty claims. I own a couple of 10 year old panels and they still produce power as new.

7) Another issue which is mentioned with regards Central Inverter vs. Micro-Inverter  is that micro-inverters are more scalable than Central inverters. If you want to increase the size of the system, it will be just a matter of adding more panels together with their micro inverters. This is a good point, however on installing the system, the central inverter can be purchased to support more panels from day. Thus it will be just a matter of adding the panels once the upgrade is performed. In this case, the upgrade will be cheaper because only the panels will need to be purchased albeit a higher initial cost of the larger central inverter. The upgrade is something which is considered from day 1 due to roof space and panels' location and it's not something which is dreamed of! Therefore the central inverter can be sized accordingly from day 1 to accommodate any upgrade which will happen in the future.

8) Central inverters can be considered as a Single point of failure. Although this is true, in my opinion it still does not justify the use of micro-inverters. A central inverter can be easily replaced since it would have been installed in a better location while micro inverters are all located under the panels. Accessibility of these micro inverters may be a problem to locate.

9) Central inverters come with a standard 5-7 year warranty which can be extended to 10-12 years while micro inverters come with a 20-25 year warranty. Well, I still have to see a micro inverter which has been on the field for 20 years! These warranty claims are based on laboratory tests and predictions while central inverters have been in the field from the time that grid-tie systems have started to mushroom across the world.

To conclude, I always follow the K.I.S.S. (Keep it Simple Stupid) principle. Why add all those electronic devices when they may be not needed (no shading and same orientation)? I think that only time will prove which is the best and therefore, most reliable technology. The central inverters already proved themselves, so we'll just have to wait for the micro-inverters to prove themselves...

The Downfall


On the 7th of November 2014, Malta was hit by a gale force storm. It hit the island in the early afternoon and although lasting for only a few hours, it caused a lot of damage across the island, from trees being uprooted to power towers and walls collapsing.

My wind turbine was not spared!
Below are the photos of the damage suffered. One of the blades got stuck due to the strong wind.



The photo below is displaying one of the guy anchoring support which got detached from the building. It was fixed to the stone building using two 8mm stainless steel raw bolts.



Once one of the guy wires got loose, the stress on the turbine pipe was too much and it collapsed!


After this, I decided that for now I won't be using the wind turbine. I will first build a stronger tower relying less on guy wires since this accident already happened another time!

I'll be posting the details of the new turbine tower once it's ready. I'll definitely build another tower because I have just bought a new set of blades from emarine - Silentwind Silent Air X Air 30 Replacement Power Blades. I obviously haven't tried them yet but these blades seem very promising!